• Home
  • Contact
  • Search
de fr it
Gussheizkörper in Aluminium- und Messingguss
  • Company
  • Products
 
  • Company
  • Products
  • Band Heaters
    • DG/DGS Nozzle Band Heaters
    • DGM High Performance Nozzle Band Heaters
    • Z/ZAW/ZWM Band Heaters with Mica insulation
    • KHK Band Heaters with Ceramic insulation
    • M/MC Band Heaters with mineral insulation
    • ZAK compact Band Heaters
    • Connection options for Band Heaters
  • HKZ/HKK/HKM Heat-Cool-Combinations
    • HKZ Heat-Cool-Combinations
    • HKK Heat-Cool-Combinations
    • HKM Heat-Cool-Combinations
    • HAK Heat-Cool-Combinations
  • Nozzle Band Heaters
    • DG/DGS Nozzle Band Heaters
    • DGM High Performance Nozzle Band Heaters
    • DAK Nozzle Band Heaters Aluminium Compact
  • High Performance Band Heaters
    • DGM Nozzle Band Heaters.
    • M/MC Heaters with mineral insulation
  • Tool Heating
    • Mica Tool Heating Frame and Flat Heaters
    • Mineral insulated Tool Heating
    • FAK/FMK Aluminium Compact Tool Heating
  • Cartridge Heaters
    • PE Cartridge Heaters 4W/cm²
    • PDE Cartridge Heaters 10W/cm²
    • PDS/PDZ Cartridge Heaters 15W/cm²
    • PDH/PZH Cartridge Heaters 15 to 20W/cm²
    • HPS/HPZ Cartridge Heaters 30W/cm²
    • Foundry-Cartridge Heaters
    • Cartridge Heater without jacket Type 0
  • Tubular Cartridge Heaters
    • RPM/RDO Tubular Cartridge Heaters
    • RPK/RDK Tubular Cartridge Heaters
    • RPS/die Casting Tubular Cartridge Heaters
    • RPI Tubular Cartridge Heaters
  • Cast-In-Heaters
    • Cast Heaters
    • Miniature Cast Heaters
  • Pre-Heaters, Dryers and Laboratory Ovens
    • TRUS, operating at temperatures - up to 140°C
    • TRUS/T, operating at temperatures - up to 300°C
    • TRUS/S, operating temperature - up to 550°C
    • ST Silo Granulate Dryer, operating temperature - up to 140°C
    • G/DGT Hopper Granulate Dryer, operating temperature 60 to 200°C
    • LT Laboratory Ovens, operating temperatures up to 300 °C max
    • WP Heating Plates, operating temperatures 50 to 300°C
  • Control Systems
    • TRG
    • MCT
    • MTR
    • Assembly of Control Systems and accessories
  • Thermocouples
    • Thermocouples and Resistance Sensors
    • Mineral Insulated Thermocouples
  • Tubular Heaters, Screw-in Cartrigde Heaters
    • Screw-in Cartridge Heaters
    • Immersion Tubular Heaters
    • Tubular Heaters/Finned Tubular Heaters
    • Heizregister
 

Download

Technical Data
Connection options
Clamp options
Options
Important order information

Picture gallery

tl_files/kit/bgguss.png
Beispiele
Aluminium- und Messing-
gussheizkörper


  • Applications
  • Shape of Cast Heaters
  • Technical Data

  • Protection category
  • Cast Heaters as Heat Cool Combinations
  • Schematic configuration
Technical Data  
Cast material: (see table 1)
Cast Tubular Heaters: With diameters 6,5 mm up to 8,5 mm, 10 mm and 15 mm
Tubular Heater jacket material: Stainless steel 1.4541 and 1.4828
Cast cooling tube: With diameters 8 mm, 10mm, 12mm, 15mm and 18mm x 1,5 mm
wall thickness
Cooling tube material: Stainless steel 1.4541. and 1.4571
Operating temperature: Up to 450°C with aluminium alloy; up to 650°C with brass alloy
Measured at the surface of the heated side
Compression strength: Aluminium 50N/cm2 corresponds to 500Kp/cm2; brass 280N/cm2 corresponds to 2800Kp/cm2
Load: Always after specific application case (see table 1)
Table 1          
Cast
material
Density in
kg/dm2
Heat
transfer
capacity in
W/(m*K)
Cast
temperature
in °C
Application
range in °C
Surface
load
W/cm2
AlSi9Cu
(226)
2,7 110-130 680-750   4 W/cm²
AlSi7Mg
(Aluminiumbronze)
2,6 160-170 680-750   4 W/cm²
CuZn39Pb
(Brass)
8,5 65-85 950-1050   6 W/cm²
Operating voltage: 230 Volt, 230/400 Volt and 400 Volt (Standard)
Dimensions: Flat Heaters: 400 x 800 mm max
Cylinder Heaters:
Diameter 700 x 800 mm max
Angular Heaters:
600 x 600 x 800 mm max
Unmachined gravity die-casting quality: Roughness depth 3,2 to 50
Unmachined sand die-casting quality: Roughness depth 12,5 to 50
Process quality gravity and sand die-casting: Rotate 0,8 to 12,5
Mill 1,6 to 12,5
Grind 0,2 to 0,8
Wall thicknesses: Standard 15 mm up to minimum 11mm on cast Tubular Heater Diameter 6,5 mm;
Standard 25 mm up to minimum 15mm on cast Tubular Heater Diameter 8,5mm
High voltage stability: 1500 Volt AC
Insulation resistance: Cold ³ 1MOhm at 500Volt DC at output
Derived power (cold):  
Capacity tolerance: ± 10% (± 5% available on request)
 