| Technical Data | |
|---|---|
| Jacket material: | 1.4541 oder 1.4301 |
| Wall thickness: | 5mm |
| Operating temperature: | 600°C at cartridge jacket |
| Load: | 15 W/cm2 max (max load 3.5 A) depending on surface temperature |
| Operating voltage: | 230 Volt |
| Hole tolerance RPK: | Hole H7 outer dimension DIN ISO 2768 medium hole H8 dependance of length (see table chap. 2.6) outer diameter ± 0,25 mm up to 0,35mm Tabelle Kap. 2.6) Outside-diameter - 0,25 mm bis -0,35 mm |
| Shaft tolerance RDK: | h8 up to 150 mm length, from 151 mm h12 (see table chap. 2.7) inner dimension DIN ISO 2768 medium ISO 2768 |
| Length tolerance RPK/RDK: | 30–100 mm length ± 3mm 101–150 mm length ± 4mm 151–300 mm length ± 5mm |
| High voltage stability: | 1000 Volt AC |
| Insulation resistance: | Cold 5 MOhm at 500 Volt DC |
| Derived power (cold): | 0,5 mA at 253 Volt DC |
| Capacity tolerance: | ±10% (± 5% available on request) |