Technichal and electrical data for PE Cartridge Heaters
| Jacket material: | stainless steel 1.4541 or 1.4301 |
| Operating temperature: | 400°C max cartridge surface |
| Load: | up to 4 W/cm² max |
| Operating voltage: | 230 Volt |
| Diameter tolerance: | ± 0.50 % min ± 0.1 mm nach DIN 2462 T1 and 2463 T1 D4 |
| Hole clearance: | = 200 mm length + 0.2 mm |
| Length tolerance: | ± 2 mm (of length related to the jacket section, length of ceramic connection head (5-7 mm) is not considered) |
| Standard connection: | 200 mm fibreglass strand, temperature stable up to 250°C max |
| Dimensions: | see PDF dimension and capacity table at right side |
| High-voltage stability: | 1.300 Volt AC at Ø 4 mm = 800 Volt AC at Ø 6,5 + Ø 8 mm = 1.000 Volt AC |
| Insulation resistance: | cold ≥ 5 MOhm at 500 Volt DC |
| Performance tolerance: | ± 10 % (± 5 % on request) |
| Derived power (cold): | ≤ 0,5 mA at 253 Volt DC |