| Technical Data | |
|---|---|
| Types: | B: Flat Heater BD: Flat Heater with pressure plate to achieve balanced contact RA: Frame Heater with metal clamp, Internal band (Heater) "one-part" Clamp frame four-parts, solid connected with the Heater on the connection side; other side loose |
| Material: | Tin plate, Steel pressure plate 3 mm and 5 mm thick. Steel Frame pressure parts 5 mm or 8 mm thick |
| Operating temperature: | up to 280°C max. measured at surface of heated side |
| Load: | up to 3.5W/cm² max. |
| Operating voltage: | 230 Volt |
| Insulation: | Mica |
| Application: | B: approx 3 mm BD: A< 200 x 200 mm with 3 mm to approx 6 mm pressure plate A>200 x 200 mm with 5 mm to approx 8 mm pressure plate RA: with 5 mm or 8mm thick clamp frame approx 8 mm or 11 mm (Indications without brass baffle plate) |
| Minimum Dimensions: | B/BD 60x20mm (length x width) RA 80x80x20 mm (Length x width x height) |
| Maximum Dimensions: | B/BD 1800x350m RA 500x500x250mm |
| Connections: | with clamp, plug or lead connection |
| Clamp gap type RA: | each side 6 mm min |
| Fixing holes: | Diameter 6 mm – for M5 thread Diameter 7 mm – for M6 thread Diameter 9 mm – for M8 thread Diameter 11 mm – for M10 thread Diameter 13 mm – for M12 thread (for optimum contact of the heater surface) |
| Postition and distribution: | 15 mm from edge and with a maximum distance in x-y axis 130 mm |
| RA Frame Heater fixing: |
Diagonal with hexagon head screws on all 4 corners |