• Home
  • Contact
  • Search
de fr it
Vorwärm- und Trockenschränke
  • Company
  • Products
 
  • Company
  • Products
  • Band Heaters
    • DG/DGS Nozzle Band Heaters
    • DGM High Performance Nozzle Band Heaters
    • Z/ZAW/ZWM Band Heaters with Mica insulation
    • KHK Band Heaters with Ceramic insulation
    • M/MC Band Heaters with mineral insulation
    • ZAK compact Band Heaters
    • Connection options for Band Heaters
  • HKZ/HKK/HKM Heat-Cool-Combinations
    • HKZ Heat-Cool-Combinations
    • HKK Heat-Cool-Combinations
    • HKM Heat-Cool-Combinations
    • HAK Heat-Cool-Combinations
  • Nozzle Band Heaters
    • DG/DGS Nozzle Band Heaters
    • DGM High Performance Nozzle Band Heaters
    • DAK Nozzle Band Heaters Aluminium Compact
  • High Performance Band Heaters
    • DGM Nozzle Band Heaters.
    • M/MC Heaters with mineral insulation
  • Tool Heating
    • Mica Tool Heating Frame and Flat Heaters
    • Mineral insulated Tool Heating
    • FAK/FMK Aluminium Compact Tool Heating
  • Cartridge Heaters
    • PE Cartridge Heaters 4W/cm²
    • PDE Cartridge Heaters 10W/cm²
    • PDS/PDZ Cartridge Heaters 15W/cm²
    • PDH/PZH Cartridge Heaters 15 to 20W/cm²
    • HPS/HPZ Cartridge Heaters 30W/cm²
    • Foundry-Cartridge Heaters
    • Cartridge Heater without jacket Type 0
  • Tubular Cartridge Heaters
    • RPM/RDO Tubular Cartridge Heaters
    • RPK/RDK Tubular Cartridge Heaters
    • RPS/die Casting Tubular Cartridge Heaters
    • RPI Tubular Cartridge Heaters
  • Cast-In-Heaters
    • Cast Heaters
    • Miniature Cast Heaters
  • Pre-Heaters, Dryers and Laboratory Ovens
    • TRUS, operating at temperatures - up to 140°C
    • TRUS/T, operating at temperatures - up to 300°C
    • TRUS/S, operating temperature - up to 550°C
    • ST Silo Granulate Dryer, operating temperature - up to 140°C
    • G/DGT Hopper Granulate Dryer, operating temperature 60 to 200°C
    • LT Laboratory Ovens, operating temperatures up to 300 °C max
    • WP Heating Plates, operating temperatures 50 to 300°C
  • Control Systems
    • TRG
    • MCT
    • MTR
    • Assembly of Control Systems and accessories
  • Thermocouples
    • Thermocouples and Resistance Sensors
    • Mineral Insulated Thermocouples
  • Tubular Heaters, Screw-in Cartrigde Heaters
    • Screw-in Cartridge Heaters
    • Immersion Tubular Heaters
    • Tubular Heaters/Finned Tubular Heaters
    • Heizregister
 

  ST120 ST250 ST500 ST750 ST1000 ST1500 ST2000 ST 4000
Shape of interior chamber Square interior chamber Square interior chamber Hexa-gonal interior chamber Hexa-gonal interior chamber Hexa-gonal interior chamber Octa-gonal interior chamber Octa-gonal interior chamber Octa-gonal interior chamber
Volume in l 200 400 800 1200 1450 2500 3000 5800
Volume in kg 120 250 500 750 1000 1500 2000 4000
Heat capacity
in kW
4,5 6 15 15 18 22,5 30 2x30
Air capacity
in m3/min
2,6 4 25 25 25 40 50 2x50
Dimension A
in mm
930x
750
1070x
800
1350x
1270
1600x
1400
2200x
1700
2250x
1800
2900x
2000
2900x
2000
Dimension C
in mm
1850 2050 2100 2250 2250 2400 2600 3350
Dimension D
in mm
515 515 350 260 260 260 260 110
Dimension E
in mm
500 625 500 1040 1212 1508 1570 1762
Drain slide valve 260x260 260x260            
Weight in kg     NW80 NW80 NW80 NW150 NW150 NW200
Shape of interior chamber 235 285 580 620 800 1100 1300 2500
The required size for a Silo Granulate Dryer is the product of:

Required drying time of the granulate x material consumption per hour

Calculation example: drying time:
3hours (polypropylene PP) material consumption: 80 kg/hour

Required capacity: 240kg

 

Results dryer size: ST 250

 
Copyright © 2012 KIT Hofheim alle Rechte vorbehalten